feat(daemon): Add UPSD (NUT) protocol support, Proxmox VM shutdown action, pause/resume monitoring, and network-loss/unreachable handling; bump config version to 4.2
This commit is contained in:
12
changelog.md
12
changelog.md
@@ -1,5 +1,17 @@
|
||||
# Changelog
|
||||
|
||||
## 2026-02-20 - 5.3.0 - feat(daemon)
|
||||
Add UPSD (NUT) protocol support, Proxmox VM shutdown action, pause/resume monitoring, and network-loss/unreachable handling; bump config version to 4.2
|
||||
|
||||
- Add UPSD client (ts/upsd) and ProtocolResolver (ts/protocol) to support protocol-agnostic UPS queries (snmp or upsd).
|
||||
- Introduce new TProtocol and IUpsdConfig types, wire up Nupst to initialize & expose UPSD client, and route status requests through ProtocolResolver.
|
||||
- Add 'unreachable' TPowerStatus plus consecutiveFailures and unreachableSince tracking; mark UPS as unreachable after NETWORK.CONSECUTIVE_FAILURE_THRESHOLD failures and suppress shutdown actions while unreachable.
|
||||
- Implement pause/resume feature: PAUSE.FILE_PATH state file, CLI commands (pause/resume), daemon pause-state polling, auto-resume, and include pause state in HTTP API responses.
|
||||
- Add ProxmoxAction (ts/actions/proxmox-action.ts) with Proxmox API interaction, configuration options (token, node, timeout, force, insecure) and CLI prompts to configure proxmox actions.
|
||||
- CLI and UI updates: protocol selection when adding UPS, protocol/host shown in lists, action details column supports proxmox, and status displays include protocol and unreachable state.
|
||||
- Add migration MigrationV4_1ToV4_2 to set protocol:'snmp' for existing devices and bump config.version to '4.2'.
|
||||
- Add new constants (NETWORK, UPSD, PAUSE, PROXMOX), update package.json scripts (test/build/lint/format), and wire protocol support across daemon, systemd, http-server, and various handlers.
|
||||
|
||||
## 2026-01-29 - 5.2.4 - fix()
|
||||
no changes
|
||||
|
||||
|
||||
Reference in New Issue