Add native local bus integrations
This commit is contained in:
@@ -0,0 +1,44 @@
|
||||
import { expect, tap } from '@git.zone/tstest/tapbundle';
|
||||
import { createModbusDiscoveryDescriptor } from '../../ts/integrations/modbus/index.js';
|
||||
|
||||
tap.test('matches manual Modbus TCP entries', async () => {
|
||||
const descriptor = createModbusDiscoveryDescriptor();
|
||||
const matcher = descriptor.getMatchers().find((matcherArg) => matcherArg.id === 'modbus-manual-tcp-match');
|
||||
const result = await matcher!.matches({
|
||||
host: '192.168.1.50',
|
||||
port: 502,
|
||||
type: 'tcp',
|
||||
name: 'Heat pump Modbus',
|
||||
unitId: 2,
|
||||
}, {});
|
||||
expect(result.matched).toBeTrue();
|
||||
expect(result.candidate?.integrationDomain).toEqual('modbus');
|
||||
expect(result.candidate?.port).toEqual(502);
|
||||
expect(result.candidate?.metadata?.unitId).toEqual(2);
|
||||
});
|
||||
|
||||
tap.test('does not guess serial RTU ports', async () => {
|
||||
const descriptor = createModbusDiscoveryDescriptor();
|
||||
const matcher = descriptor.getMatchers().find((matcherArg) => matcherArg.id === 'modbus-manual-tcp-match');
|
||||
const result = await matcher!.matches({
|
||||
type: 'serial',
|
||||
host: '/dev/ttyUSB0',
|
||||
name: 'RS485 adapter',
|
||||
}, {});
|
||||
expect(result.matched).toBeFalse();
|
||||
expect(result.reason).toContain('Serial RTU');
|
||||
});
|
||||
|
||||
tap.test('validates Modbus TCP candidates', async () => {
|
||||
const descriptor = createModbusDiscoveryDescriptor();
|
||||
const validator = descriptor.getValidators()[0];
|
||||
const result = await validator.validate({
|
||||
source: 'manual',
|
||||
integrationDomain: 'modbus',
|
||||
host: 'plc.local',
|
||||
}, {});
|
||||
expect(result.matched).toBeTrue();
|
||||
expect(result.candidate?.port).toEqual(502);
|
||||
});
|
||||
|
||||
export default tap.start();
|
||||