feat(specs): add whole-house water system and cellar datacenter specifications with cross-document coordination updates
This commit is contained in:
@@ -4,7 +4,7 @@ The open specification for building maximally maintainable, healthy homes.
|
||||
|
||||
## What This Is
|
||||
|
||||
A complete, opinionated building specification for a Baufritz timber-frame house engineered around **clean-room-level indoor air quality** and **lifetime maintainability**. Every system — air filtration, heating, flooring, wiring — is designed so that components can be inspected, serviced, and replaced without destructive intervention.
|
||||
A complete, opinionated building specification for a Baufritz timber-frame house engineered around **clean-room-level indoor air quality**, **laboratory-grade water purity**, **self-hosted infrastructure**, and **lifetime maintainability**. Every system — air filtration, water treatment, heating, flooring, plumbing, datacenter — is designed so that components can be inspected, serviced, and replaced without destructive intervention.
|
||||
|
||||
## Specification Documents
|
||||
|
||||
@@ -14,6 +14,8 @@ A complete, opinionated building specification for a Baufritz timber-frame house
|
||||
| [02 — Sensors & Automation](specs/02-sensor-automation-spec.md) | Per-room air quality sensors, KNX/Zigbee architecture, Home Assistant integration, demand-controlled ventilation |
|
||||
| [03 — Baufritz Coordination](specs/03-baufritz-coordination-spec.md) | Technical room, duct routing, airtightness, radon protection, construction checkpoints |
|
||||
| [04 — Flooring & Ceiling](specs/04-flooring-ceiling-spec.md) | Lindner NORTEC Doppelboden raised floor, WOODline parquet, Plafotherm AirHybrid radiant ceiling |
|
||||
| [05 — Water System](specs/05-water-system-spec.md) | POE reverse osmosis, 316L stainless steel plumbing, ceiling-routed distribution, leak detection |
|
||||
| [06 — Home Datacenter](specs/06-datacenter-spec.md) | Cellar, 4x 42U racks, closed-loop cooling, heat recovery, goods elevator, UPS, structured cabling |
|
||||
|
||||
## Key Design Principles
|
||||
|
||||
@@ -22,6 +24,10 @@ A complete, opinionated building specification for a Baufritz timber-frame house
|
||||
- **Heating via ceiling** (Plafotherm AirHybrid), not floor — fast response, furniture-independent, integrates MVHR supply air
|
||||
- **Raised access floor** (Lindner NORTEC Doppelboden) — individually liftable 600x600 mm panels for full access to services underneath
|
||||
- **Dry construction throughout** — no wet trades, ideal for Baufritz timber-frame
|
||||
- **Whole-house POE reverse osmosis** — 95-99% TDS removal, remineralized, UV-sterilized, PFAS/microplastic-free
|
||||
- **316L stainless steel plumbing** — food-grade, zero leaching, press-fit, routed accessibly under suspended ceiling
|
||||
- **Home datacenter in cellar** — 4x 42U racks, 10 kW closed-loop cooling, N+1 redundancy, heat recovery heats the house in winter
|
||||
- **Goods elevator** — 1000 kg capacity, cellar to ground floor, handles fully loaded server racks
|
||||
- **Positive pressure** (+3-5 Pa) — unfiltered air never enters the building envelope
|
||||
|
||||