The previous migration only checked for upsList field, but saveConfig()
strips upsList when saving, creating a race condition. If the daemon
restarted with a partially-migrated config (upsDevices with flat structure),
the migration wouldn't run because it only looked for upsList.
Now shouldRun() also detects:
- upsDevices with flat structure (host at top level, no snmp object)
And migrate() handles both:
- config.upsList (pure v3)
- config.upsDevices with flat structure (partially migrated)
This fixes the "Cannot read properties of undefined (reading 'host')"
error that occurred when configs had upsDevices but flat structure.
The v3→v4 migration was only renaming upsList to upsDevices without
transforming the device structure. V3 had a flat structure with SNMP
fields directly on the device object, while v4 expects a nested 'snmp'
object.
This commit fixes the migration to:
- Move host, port, community, version, etc. into nested snmp object
- Convert version from string to number
- Add default timeout (5000ms)
- Create thresholds object with defaults
- Preserve all SNMPv1, v2c, and v3 authentication fields
Also includes install.sh fix for better non-interactive handling.
Major improvements:
- Created color theme system (ts/colors.ts) with ANSI colors
- Enhanced logger with colors, table formatting, and styled boxes
- Fixed daemon exit bug - now stays running when no UPS configured
- Added config hot-reload with file watcher for live updates
- Beautified CLI help output with color-coded commands
- Added showcase test demonstrating all output features
- Fixed ANSI code handling for perfect table/box alignment
Features:
- Color-coded messages (success=green, error=red, warning=yellow, info=cyan)
- Status symbols (●○◐◯ for running/stopped/starting/unknown)
- Battery level colors (green>60%, yellow 30-60%, red<30%)
- Table formatting with auto-sizing and column alignment
- Styled boxes (success, error, warning, info styles)
- Hot-reload: daemon watches config file and reloads automatically
- Idle mode: daemon stays alive when no devices, checks periodically
Daemon improvements:
- No longer exits when no UPS devices configured
- Enters idle monitoring loop waiting for config
- File watcher detects config changes in real-time
- Auto-reloads and starts monitoring when devices added
- Logs warnings instead of errors for missing devices
Technical fixes:
- Strip ANSI codes when calculating text width for alignment
- Use visible length for padding calculations in tables and boxes
- Properly handle colored text in table cells and box lines
Breaking changes: None (backward compatible)
- Remove tapbundle and @git.zone/tstest dependency
- Use Deno.test() and @std/assert for all tests
- Update test imports to use jsr:@std/assert
- All 10 logger tests passing with native Deno test runner
- Simplified test configuration in deno.json
- Tests are now completely dependency-free (only standard library)
- Update tapbundle imports from @push.rocks to @git.zone/tstest
- Change all test file imports from .js to .ts extensions
- Tests verified working with Deno runtime
- All 10 logger tests passing
- SNMP tests ready for Deno execution
- Created deno.json configuration
- Updated all imports to use npm:net-snmp@3.20.0
- Changed all Node.js built-in imports to node: specifiers
- Updated all .js extensions to .ts in imports
- Created mod.ts as Deno entry point
- Ready for Phase 3: CLI simplification